Type tests and environmental conditions

Phenomena Test Description Ethernet Technologies
ESD EN 61000-4-2 Enclosure contact ± 6 kV
Enclosure air ± 8 kV
RF field AM modulated IEC 61000-4-3 Enclosure 10 V/m 80% AM (1 kHz),
80 - 1000 MHz
20 V/m 80% AM (1 kHz),
800 - 1000 MHz
10 V/m 80% AM (1 kHz),
1400 - 2100 MHz
5 V/m 80% AM (1 kHz),
2100 - 2500 MHz
Fast transient EN 61000-4-4 Signal ports ± 2 kV
Power ports ± 2 kV
Surge EN 61000-4-5 Signal ports unbalanced ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced ± 2 kV line to earth, ± 1 kV line to line
Power ports ± 2 kV line to earth, ± 1 kV line to line
RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 kHz), 0.15 - 80 MHz
Power ports 10 V 80% AM (1 kHz), 0.15 - 80 MHz
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m
Pulse magnetic field EN 61000-4-9 Enclosure 300 A/m
Mains freq. 50 Hz EN 61000-4-16 Signal ports 100 V 50 Hz line to earth
Mains freq. 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line
Voltage dips and interruption EN 61000-4-29 DC power ports 10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & -20% below rated voltage
Radiated emission EN 61000-6-4 Enclosure Class A
FCC part 15 Enclosure Class A
Conducted emission EN 55022 DC power ports Class B
Dielectric strength EN 60950 Signal port to other isolated ports 2 kVrms 50 Hz 1 min
Power port to other isolated ports 2 kVrms 50 Hz 1 min
Temperature Operating -40 to +70°C
Storage & Transport -40 to +85°C
Humidity Operating 5 to 95% relative humidity
Storage & Transport 5 to 95% relative humidity
Altitude Operating 2 000 m / 70 kPa
Service life Operating 10 year
Vibration IEC 60068-2-6 Operating 7.5 mm, 5 - 8 Hz
2 g, 8 - 500 Hz
(Wall-mounted or DIN-rail mounted using TH 35-15 according to EN 60175)
Shock IEC 60068-2-27 Operating 15 g, 11 ms
(Wall-mounter or DIN-rail mounted using TH 35-15 according to EN 60175)
Enclosure UL 94 Aluminium / Zink Flammability class V-0